What it covers
The sequence for stripping the old covering, checking the deck, laying insulation and applying the new membrane. It records the edge protection and access in place before work starts, how LPG cylinders are stored and checked, and the fire watch kept after the last flame each day.
Hazards and controls
Falls from the roof edge, controlled by scaffold or guardrails before anyone goes up. Falls through a fragile or rotten deck, controlled by checking the deck and boarding across weak areas. Fire from torch-on work, controlled by a hot works permit, a cold-applied system where the specification allows, and a fire watch. Then LPG leaks, burns, falling debris and manual handling of rolls and boards. Controls follow the hierarchy, so edge protection and the permit come before PPE.
Permits and competence
Torch-on roofing needs a hot works permit issued each day before any flame is lit. The method statement names the permit, the roofing qualifications and the LPG training required, so a principal contractor can check it at a glance.
FAQ
- Does it cover hot works for torch-on membranes?
- Yes. The hot works permit and the fire watch are part of the numbered method, and fire is in the risk assessment with the matching controls.
- Does it cover fragile roofs?
- Yes. Checking the deck before work is a step in the method, and a fall through a fragile surface is in the risk assessment.
- Can I add my own steps?
- Yes. Download it as Word and edit anything to match the roof, the membrane and the access you are using.
- What does it cost?
- Your first document is free. After that, £15 each, three for £35, or ten for £89. No subscription. You can read a full sample before you decide.